0 541 290 30 70
Copyright 2023 ANOD TEKNOLOJİ A.Ş.. All Rights Reserved By
DinamikSoft

Efficient Use of Angiography Device

The angiogram device is one of the most advanced imaging systems used in the diagnosis and treatment of vascular diseases. Angiogram procedures are of great importance, especially in the fields of cardiology and neurology. However, improper use of the device can both reduce image quality and lead to unnecessary energy consumption. As Anod, we offer professional support to optimize the use of the angiogram device and ensure that it operates at the highest efficiency.

Why is the Efficient Use of the Angiogram Device Important?

Provides High Quality Images: Clear and accurate images improve diagnosis and treatment processes.
Increases Patient Safety: Using the right dose of radiation prevents unnecessary radiation exposure of patients.
Extends Device Life: Regular maintenance and correct use ensure that the angiogram device components operate smoothly for a longer period of time.
Reduces Costs: Reduces unnecessary energy consumption and the need for replacement of spare parts.
Efficient Use Methods of the Angiogram Device

1. Calibrate the Device Regularly

The angiogram device should be calibrated before each use or at certain intervals.
The accuracy of the X-ray tube, detector and sensors should be checked.
Correct calibration provides a safer environment for patients by preventing unnecessary radiation doses.
2. Optimize Image Quality

X-ray detectors should be cleaned regularly to obtain clear images.
Appropriate settings should be made to prevent unnecessary energy consumption when working at high resolution.
More detailed analyses should be performed by integrating with CT and other systems.
3. Use the Correct Radiation Dose

The angiogram should be operated with the lowest possible radiation dose.
X-ray tube and detector systems should be optimized to prioritize patient safety.
Appropriate filtering techniques should be used to reduce radiation exposure.
4. Reduce Angiography Procedure Time

Long-lasting angiograms can be uncomfortable for patients and cause unnecessary energy consumption.
The angiogram should be used at the best angles and settings to prevent unnecessary re-exams.
Data processing can be accelerated with additional modules such as RFPA and MSUP devices.
5. Use the Cooling System Effectively

Angio device may overheat due to high power consumption.
Cooling fans and air flow should be checked regularly.
X-ray tube cooling systems should be kept at optimum levels with regular maintenance.
6. Get Periodic Maintenance and Technical Support

Angio device should be subjected to technical checks at regular intervals.
X-ray spare parts and sensor systems should be replaced at certain intervals to ensure the longevity of the device.
The Anod technical team ensures that angi systems always operate at the highest efficiency.
How Often Should Angiography Device Maintenance Be Performed?

In standard use: Detailed checks should be performed every 6 months.
In intensively used devices: Maintenance is recommended every 3 months.
After new part replacement: Calibration and tests should be performed.
Anod’s Angiography Device Technical Support Services

Fast service solutions with experienced engineering team
Long-lasting use with original spare parts support
Periodic maintenance and calibration services
Ensuring patient and user safety with radiation safety tests
If you want to increase your Angiography device efficiency and ensure that it operates at its best performance, Anod is always with you!