Mammography devices are one of the most important imaging systems used in breast cancer diagnosis. The high accuracy of these devices is critical for early diagnosis. However, over time, due to intensive use or technical reasons, mammography devices may give errors and imaging quality may decrease. As Anod, we offer professional solutions in mammography device error correction processes.
Common Errors and Solutions in Mammography Devices
1. Deterioration in Image Quality
Symptoms:
Mammography images may be blurry or low contrast.
Unwanted lines, spots or pixelation may occur in the images.
Solution:
Detector calibration should be performed.
X-ray tube voltage settings should be checked.
Errors in image processing algorithms should be evaluated with software tests.
2. Mammography Device Turns Off During Capture
Symptoms:
The device suddenly turns off or gives an error during capture.
When it is turned on again, the startup process takes a long time.
Solution:
The power supply and electrical connections should be checked.
Cooling systems should be tested, and it should be determined whether the device shuts down due to overheating.
The X-ray tube may be overloaded, and the condition of the tube should be examined.
3. Mammography Device Gives Radiation Dose Error
Symptoms:
The device gives a low or high radiation dose warning.
The imaging process does not start for patient safety.
Solution:
The X-ray tube output power should be tested and the radiation dose should be measured.
Dose settings should be optimized according to factory standards.
Filtering systems and detectors should be checked to ensure that correct measurements are made.
4. Patient Compression Mechanism Does Not Work
Symptoms:
The patient compression system (compression plate) in the mammography device does not move.
The system does not respond in manual or automatic mode.
Solution:
Mechanical movement systems should be examined, lubricated and cleaned.
Electric motors should be checked, and it should be determined whether there is a problem with the power connections.
The compression system may require a software update, and it should be ensured that the device is running on the latest version.
5. The Image Acquisition Process Takes a Long Time
Symptoms:
After the acquisition is completed, the images take longer to process than normal.
Patient information cannot be saved to the system or image transfer is delayed.
Solution:
The computer system and PACS integration should be checked for problems.
The image processing software should be updated, and if an old or incompatible version is used, it should be corrected.
Hardware components should be tested to increase data transfer speed.
Mammography Device Error Troubleshooting Process
As Anod, we meticulously carry out the error troubleshooting processes of mammography systems:
Error Detection and Analysis
Error codes are examined and the warnings given by the device are analyzed.
Imaging components and mechanical parts are checked in detail.
Part Repair or Replacement
Components such as X-ray tubes, detectors or power supplies are repaired or replaced.
Mechanical components are checked to determine whether there is any jamming or wear.
Calibration and Software Updates
The device's radiation dose, contrast settings and detector sensitivity are optimized.
The device software is updated to the best performance level.
Test and Approval Process
After the device is repaired, detailed test shots are performed.
After the image quality and patient safety are verified, the device is put back into service.
How Often Should Mammography Device Maintenance Be Performed?
In standard use: Periodic maintenance should be performed every 6 months.
In heavily used devices: Technical checks are recommended every 3 months.
After new component replacement: Calibration and testing procedures should be performed.
Anod's Mammography Device Technical Support Services
We offer fast fault detection and professional solutions.
We provide long-lasting solutions with the use of original spare parts.
We guarantee the best performance in imaging systems.
We ensure that your devices always operate at the highest efficiency with periodic maintenance plans.
If you need technical support regarding your mammography device, Anod is always with you!